Installation

Installation  Tips

Each AdvanSafe-200 primary unit can be connected to up to 1 secondary unit.

For installation, we recommend:

Therefore, we recommend the following configuration depending on the width of the store entrance:

Primary/Secondary installation

Follow the instructions in the Installation Guide found at Download files chapter at the end of the page.

AdvanSafe-200-Suspension-Mount-Installation.pdf

Wire/suspension mount units

AdvanSafe-200-Ceiling-Mount-Installation.pdf

Ceiling mount units

The diameter of the steel cable is 0.8 mm

AdvanSafe Secondary

AdvanSafe-200 Secondary units are extension units without active RF components. The Secondary can be thought as a beam switching antenna plus an LED bar. Secondary units contain three different connectors:

The three cables must be connected for proper Secondary operation

Secondary units are used to increase the reading area of AdvanSafe by attaching one AdvanSafe Secondary to an AdvanSafe Primary.

Secondary units are configured from within the Primary unit they are connected to.

Secondary units do not have IP address or any other data interface for a remote data connection.

Only one Secondary can be connected to AdvanSafe-200 Primary

Physical Connection

Follow the image below to connect AdvanSafe-200 Primary and Secondary (remember to power the AdvanSafe Primary after doing the other two connections):

Secondary connection pictures

For a proper Secondary operation, the three connection cables must be present:

AdvanNet Configuration

Go to the RFID tab of AdvanSafe Primary and configure a new antenna on the port where the Secondary is connected.

Please note the order of the beams must follow the sequence displayed:

Go to the Events & Actions tab and configure an event to light up the LED (GPO_ACTION) of the Secondary when there is an alarm detected by the Secondary. If the Secondary is connected to the data cable number 2, the Line has to be 2.

Installation tips

Which is the maximum recommended distance between Primary and Secondary?

We do not recommend using cables larger than 5 meters.

What is the maximum height AdvanSafe will work at?

There is no single answer to that question, several factors must be taken into account:

However, there are some simple recommendations:

Which materials and/or conditions may interfere AdvanSafe operation?

Generally speaking, AdvanSafe is quite robust against external interference. Some of the known sources of interference are:

The human body is generally the biggest interference system. It is also required to test the final system to verify it works to meet requirements.

What is the coverage of AdvanSafe-200

The linear coverage of one AdvanSafe-200 unit is between 150 cm and 200 cm.

The distance  (central point) between AdvanSafe-200 units must be between 150 cm and 200 cm.

What are the safety margins

As a general rule, the safety margins around AdvanSafe-200 units are: installation height /2 + 50 cm