External sounder
Introduction
This pages defines the procedure to install an external sounder to ADGR-100
AdvanGuard-100 units do not contain the required parts to build the external sounder. They must be acquired separately, links to online dealers are provided.
Requirements
The following is the list of HW requirements
1 x ADGR-100 with access top the I/O connectors
1 x sounder. For example: https://uk.rs-online.com/web/p/electronic-sounders/2279999
(Eaton Fulleon Roshni Red 32 Tone Electronic Sounder, 9 → 28 V dc, 107dB at 1 Metre, Surface Mount, IP54)
24 V / 1A Power supply. For example Keonn PPWS-24V-2A-lkst
Electrical cable pair. The following are the different options for the cable width.
AWG24: up to 12 m
AWG21: up to 24 m
AWG18: up to 48 m
Installation
Follow the connection diagram
2. Configure AdvanNet
By default the configuration does not use the Relay lines used for the sounder connection.
Make sure the Events&Actions settings have the following configuration
3. Verify the sounder
4. Persist settings