AdvanPay Button
Located either at the top of the flush mount configuration or in a remote controller the function of an AdvanPay button is to start/stop the RF operation of the device and cycle between the available ADVANPAY read modes.
Normal operation
The behavior is as follows:
If the button is just pressed (without holding it), it will make the AdvanPay:
Start reading: The led will start blinking.
Stop reading: The led will stay steady.
If the button is pressed and held for more than 4 seconds, it will change the read mode. This will be reflected on the LEDs (read modes explanation):
Green LED: ADVANPAY_PAYMENT read mode.
Red LED: ADVANPAY_RETURN read mode.
Blue LED: ADVANPAY_READONLY read mode.
Special cases
If the device is configured to work in Autonomous mode or Sequential mode the LED will be:
AUTONOMOUS: All three LEDs are used
SEQUENTIAL: Blue and Green LEDs are used.
Changing the defaults
We have several OS Upgrades that allow changing the default functionality of the button. For the instructions on how to apply them, please click here.
fixConnectorsDisablePayButton : This one disables the button altogether
fixConnectorsRestorePayButtonDefaults : This one restores the button to the default vaules.
Note: disabling the button using the first update will cause the following updates to fail, as there will be no longer a button to configure
advanPayRemovePaymentFromButton : This one removes ADVANPAY_PAYMENT from the list of read modes when cycling with a long press of the button
advanPayRemoveReadOnlyFromButton : This one removes ADVANPAY_READONLY from the list of read modes when cycling with a long press of the button
advanPayRemoveReturnFromButton : This one removes ADVANPAY_RETURN from the list of read modes when cycling with a long press of the button
advanPayRestoreReadModesButton : This one restores the list of read modes to cycle to its default values.